Blackout Math

What size backup power do you need?

Tick what has to keep running and for how long. The board shows what covers it.

How long is the outage?

How the numbers work

Add the running watts of everything that has to run at the same time. Then add the single highest starting-watts figure on top, because motors such as a refrigerator compressor or a sump pump draw extra for a moment when they start, and rarely start together. Champion Power Equipment and Generac print this rule with their wattage charts, and Westinghouse’s manual adds the highest starting watts the same way. An item whose chart lists no starting figure adds nothing.

Energy is running watts times hours, with a refrigerator counted at about a third of the time, because its compressor cycles. Other items count the hours a day you set, and an outage shorter than a day counts them up to its length.

A power station lasts about its watt-hours times 80%, divided by the average watts. BLUETTI prints a 80% factor for the loss in converting battery power to wall-outlet power; Anker prints 0.85 to 0.90. Home batteries are counted at the energy their makers state (Tesla gives nominal energy, Enphase usable), without that factor. Real runtime is shorter in cold and with older cells.

A standby generator on a gas line is shown as running for as long as its gas supply holds; its spec sheet gives the fuel it burns at full load. Air-cooled home standby generators are rated by continuous output and have no separate surge rating (Generac), so the starting load has to fit inside the rated output, on natural gas.

The sizing rating is never a promise of what your own home needs. Nameplates differ, makers' charts differ (a refrigerator is 400 W on Champion’s chart and 700 W on Generac’s, and the tool uses the higher), and anything wired into your home panel is for a licensed electrician.

The loads in the calculator

Where every number comes from

Each figure is copied from the maker’s own page or document, apart from the refrigerator’s cycling, which comes from a Virginia Tech Extension guide. Read 19 November 2026. Prices change; the link shows today’s.